Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
4-20 mA Loop Powered Two Wire Oxygen Transmitter
OxyTrans
The Edgetech Instruments Model OxyTrans is an easy to use, accurate and economical way to measure Oxygen at trace and % levels. A simple display and one point calibration allows for a quick start of the instrument.
-
product
AC Current Isolated Sensor Two / Four Wire Transducer
TSCT (Average Sensing) / TFCT (TRUE RMS)
Kusam Electrical Industries Limited
• Transform Input: AC 5~400A directly into DC 4~20mA, no need external CT.• Suitable for application with high waveform distortion :(Frequency converter, Motor, SCR )• High accuracy <0.5%• High response time• High stability, easy connection.
-
product
Mini Coax, Contact, ITA, two .025" Square Wire Wrap Posts
610103129
Mini Coax, Contact, ITA, two .025" Square Wire Wrap Posts
-
product
Mini Coax, Contact, Receiver, two .025" Square Wire Wrap Posts
610104140
Mini Coax, Contact, Receiver, two .025" Square Wire Wrap Posts
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI Differential Fault Insertion Switch Modules
Pickering's PXI Differential Fault Insertion Switch Modules support multiple channels of two-wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to externally applied fault conditions. *Two module types are available: Two wire fault insertion module suitable for CAN Bus and FlexRay.*High bandwidth two wire fault insertion module suitable for Gigabit Ethernet, AFDX and BroadR-Reach.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Thermocouples
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
product
Contact Temperature Sensors
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
Advanced Wire Tracers
Amprobe’s Advanced Wire Tracers provide accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification, including two optimal frequencies for both energized and de-energized wire and breaker tracing in walls, ceilings, and floors.
-
product
Winch & Reel For 1D VES Sounding
The winch/reel is only for 1D vertical resistivity sounding(VES) survey, which will improve the working efficency in 1D geophysical investigation. There are two types: one for 200m copper wire, the other for 500m copper wire.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
42-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
product
Temperature Transmitters
Conversion of Thermocouple, RTD, millivolt and resistance signals from field sensors is accomplished using DEVAR two wire signal transmitters.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Ohm-Stat Guardian Pro Constant Monitor
Tests two people and two wriststrapsLED and buzzerNIST calibration includedWorks with all single wire capacitance wrist strapsAll cords suppliedCE markCan be calibratedProduct conforms to the ESD S.20.20 spec standards110v AC powerGround dock included
-
product
Cable Length Meter
Shanghai Beha Electronics Co., Ltd.
*Cable length measurement by pulse reflection measurement, only required one cable end (with two wires)*Resistance measurement*Acoustic continuity test
-
product
Three Phase Meter Test Bench
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
RTD Measurement for VMEbus
VME390
The VME390 features 24 two, three or four wire high-accuracy PT100 measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued.
-
product
Phase Testers